  "opencollection": "1.0.0",
  "info": {
    "name": "Devialet IP Control Devices API",
    "version": "1"
  },
  "items": [
    {
      "info": {
        "name": "Devices",
        "type": "folder"
      },
      "items": [
        {
          "info": {
            "name": "Get device information",
            "type": "http"
          },
          "http": {
            "method": "GET",
            "url": "http://{deviceAddress}/ipcontrol/v1/devices/:deviceId",
            "params": [
              {
                "name": "deviceId",
                "value": "",
                "type": "path",
                "description": "Device identifier. The only value supported today is `current`, which refers to the dispatcher — the device that received the request."
              }
            ]
          },
          "docs": "Query general information pertaining to the designated device — identifiers, model, firmware version, serial number, role, and device name. Minimal firmware: DOS >= 2.14. Also available as a NOTIFICATION channel in a future revision (subscriptions are not yet implemented)."
        },
        {
          "info": {
            "name": "Power off the device",
            "type": "http"
          },
          "http": {
            "method": "POST",
            "url": "http://{deviceAddress}/ipcontrol/v1/devices/:deviceId/powerOff",
            "params": [
              {
                "name": "deviceId",
                "value": "",
                "type": "path",
                "description": "Device identifier. The only value supported today is `current`, which refers to the dispatcher — the device that received the request."
              }
            ],
            "body": {
              "type": "json",
              "data": "{}"
            }
          },
          "docs": "Turn off the designated device. Exiting OFF mode is only possible by pressing a physical button on the device. Minimal firmware: DOS >= 2.16."
        },
        {
          "info": {
            "name": "Restart the device",
            "type": "http"
          },
          "http": {
            "method": "POST",
            "url": "http://{deviceAddress}/ipcontrol/v1/devices/:deviceId/restart",
            "params": [
              {
                "name": "deviceId",
                "value": "",
                "type": "path",
                "description": "Device identifier. The only value supported today is `current`, which refers to the dispatcher — the device that received the request."
              }
            ],
            "body": {
              "type": "json",
              "data": "{}"
            }
          },
          "docs": "Reboot the designated device. The device becomes unresponsive during the reboot. Minimal firmware: DOS >= 2.16."
        },
        {
          "info": {
            "name": "Reset the device to factory settings",
            "type": "http"
          },
          "http": {
            "method": "POST",
            "url": "http://{deviceAddress}/ipcontrol/v1/devices/:deviceId/resetToFactorySettings",
            "params": [
              {
                "name": "deviceId",
                "value": "",
                "type": "path",
                "description": "Device identifier. The only value supported today is `current`, which refers to the dispatcher — the device that received the request."
              }
            ],
            "body": {
              "type": "json",
              "data": "{}"
            }
          },
          "docs": "Reset the designated device to factory settings and reboot it. This erases all network credentials — unless the device is connected by Ethernet it becomes inaccessible. It does not roll back the firmware version. Minimal firmware: DOS >= 2.16."
        }
      ]
    }
  ],
  "bundled": true
}